隔声性能SOUND INSULATION PERFORMANCE

There are two types of acoustic functions: sound insulation and noise absorption. This Section explains common sound insulation terms. [Noise absorption is addressed later in this Section]

术语和定义ACOUSTIC TERMS AND DEFINITIONS

Rw

计权隔声量Weighted Sound Reduction Index

Rw describes the airborne sound insulating power of a building element. It is a laboratory measured value that can apply to walls, ceiling/floors,ceiling/roofs,doors or windows. The higher the number, the greater the sound insulating power of the building element.

For example, an increase in the Rw of a wall by 10 points will reduce the perceived loudness of sound passing through the wall by about half. Table 1 shows how the sound insulating effectiveness of walls depends on their Rw or Rw + Ctr values.

Rw + Ctr低频校正

Rw Plus Spectrum Adaptation Term

Rw + Ctr is equal to Rw with the addition of a low frequency sound correction, Ctr. The use of Rw + Ctr has been adopted due to the increase in low frequency sound sources such as surround sound systems, traffi c and aircraft noise, drums and bass guitars.

Two walls can have the same Rw rating but have different resistance to low frequency sound, thus a different Rw + Ctr.

DnTw and DnTw + Ctr

Measured On-Site

These values are the equivalent of Rw and Rw + Ctr, but measured on-site. Rw is the value measured in an acoustic laboratory, while DnTw is measured on-site.

An on-site measured value of DnTw + Ctr is permitted to be 5 points lower than the Rw + Ctr value. Where the BCA may call for an Rw + Ctr ≥ 50, the same requirement may be satisfied by measuring DnTw + Ctr ≥ 45 on-site.

现场测量,可以比BCA要求低5

Ln,w + Ci

冲击隔声等级Impact Sound Insulation Rating

Ln,w + Ci describes how easily impact sound travels through a wall or floor. Impact sound is generated by sources such as dryers, washing machines and heeled shoes on a wooden floor.

Unlike Rw values, better performing walls or floors have lower values. Therefore when specified, Ln,w + Ci values are maximums while Rw values are minimums. For example, the BCA requires some floors to have Ln,w + Ci < 62.

Impact Sound Insulation

Walls that have Impact Sound Insulation are defined in the BCA as walls that do not have any rigid mechanical connection between two separate leaves except at the perimeter.

Systems in this manual that satisfy this BCA requirement are staggered stud plasterboard walls with no noggins, and walls that use resilient mounts.

Impact Sound Insulation with Discontinuous Construction

Discontinuous Construction is defi ned in the BCA as walls that have a gap of at least 20mm between two separate leaves. Double stud plasterboard walls are classed as ‘discontinuous’. [Refer to the BCA for a complete definition]

TABLE 1 Effect of Various Walls on Sound Insulation Performance

声学要求ACOUSTIC REQUIREMENTS

Performance requirements of the BCA relating to sound transmission and insulation can be satisfied by one of the following three options:

1. Deemed-to-Satisfy Construction

Construct a wall or ceiling system that complies with the deemed-to-satisfy provisions of the BCA Specifi cation F5.2– 2. This section of the BCA details generic systems that satisfy the acoustic BCA requirements. However in general,more efficient solutions can be found in this manual.

BCA的这一部分详细介绍了满足声学BCA需求的通用系统。然而,一般来说,在本手册中可以找到更有效的解决方案。

2. Laboratory Test or Acoustic Engineering

Construct a wall or ceiling system with an acoustic rating from this manual. The systems in this manual were either laboratory tested according to the relevant acoustic testing standard or were given an Acoustic Opinion made by Day Design Pty Ltd consulting acoustical engineers of Sydney NSW, or Marshall Day acoustic software.

Acoustic testing laboratories are designed to ensure that fl anking paths do not occur. Tested partition systems are constructed with extreme care to achieve optimum performance. For these reasons, on-site performance may be different to laboratory performance.

3. On-Site Testing

Conduct on-site acoustic testing on a wall or ceiling system. This is a ‘verification method’ accepted by the BCA to confirm the performance requirements are met.Also the effectiveness of the complete installed system can be verified by on-site acoustic testing.

这一部分是对可以接受的数据的三个来源:1/BCA已经列明的;2/实验室数据;3/现场测试数据

更高的声学要求HIGHER ACOUSTIC REQUIREMENTS

Where performance is critical or noise is higher than normal, accredited acoustic engineers should be consulted. Their role is to ensure that design and construction will meet any specific requirements.

Acoustic predictions for systems not published in Knauf technical literature can often be generated by acoustic modelling software. Contact Technical Services for an acoustic prediction based on the Knauf product range.

The Association of Australian Acoustical Consultants (AAAC) offer detailed guidance on acceptable acoustic performance. They have published their own star rating system. Ratings range from 2 to 6 stars and are based on field testing by an AAAC consultant to verify that they have been achieved. More information about AAAC Star Ratings for apartments and townhouses is available at www.aaac.org.au

ACOUSTIC TESTING AND ACTUAL PERFORMANCE

Attention to detail during construction is important for achieving good acoustics, as performance is governed by the weakest link in the system. Performance of installed acoustic systems may fall short of laboratory measured results. Acoustic measurements in a typical laboratory test represent the maximum performance that can be achieved. Meticulous care goes into laboratory installation of the system.

Actual site conditions are usually less than ideal and sound flanking paths normally exist around the perimeter of the system. Flanking paths may be minimised by sealing the perimeter with acoustic sealant, including behind the cornice and by installing services using acoustically rated details.

声学设计DESIGNING FOR ACOUSTIC PERFORMANCE

Acoustic performance is easier and cheaper to achieve if it is considered before construction begins.划重点:一定要在施工前考虑才能节省造价

Good acoustic design includes:

Flanking paths are ways sound can travel around barriers, such as through windows, ceiling cavities,under doors and along services.

ACOUSTIC PERFORMANCE OF WALL PARTITIONS

Acoustic performance listed in systems tables may vary due to decreased stud spacing and increased steel stud thickness (BMT) to our tested systems.Acoustic performance may also vary due to any additional linings on battens or on separate stud walls.

The sound insulating capability of a basic wall or ceiling system can be upgraded by using a combination of:

在基本性能上进行升级的手段

SoundShield is a plasterboard with enhanced acoustic qualities. SoundShield has a super high-density* core which helps to resist the transmission of noise into rooms.

* The denser the plasterboard, the better it will resist sound transfer. 返回搜狐,查看更多

责任编辑:

平台声明:该文观点仅代表作者本人,搜狐号系信息发布平台,搜狐仅提供信息存储空间服务。
阅读 ()
推荐阅读

两个鬼故事nba今日直播光之子攻略湄公河惨案牺牲的警察公司起名外语甜蜜十一月巨大少女起买翡翠网名起名软件免费下幼儿园男教师起名建党100周年庆祝大会太原丁香园3.5mm耳机接口网易popo下载豆制品加盟店公司起名标准黄秋生在台隔离期间被诈骗起名与生肖属鸡宝宝起名打分改名 起名魔幻小说推荐2020年鼠女宝宝起名宜用字男孩起什么名字起名字小说女帝的大内总管好高骛远什么意思四个雷念什么我的邻居民是exo第三集企业工厂起名大全参照蒲式耳远得要命的爱情剧情介绍少年生前被连续抽血16次?多部门介入两大学生合买彩票中奖一人不认账让美丽中国“从细节出发”淀粉肠小王子日销售额涨超10倍高中生被打伤下体休学 邯郸通报单亲妈妈陷入热恋 14岁儿子报警何赛飞追着代拍打雅江山火三名扑火人员牺牲系谣言张家界的山上“长”满了韩国人?男孩8年未见母亲被告知被遗忘中国拥有亿元资产的家庭达13.3万户19岁小伙救下5人后溺亡 多方发声315晚会后胖东来又人满为患了张立群任西安交通大学校长“重生之我在北大当嫡校长”男子被猫抓伤后确诊“猫抓病”测试车高速逃费 小米:已补缴周杰伦一审败诉网易网友洛杉矶偶遇贾玲今日春分倪萍分享减重40斤方法七年后宇文玥被薅头发捞上岸许家印被限制高消费萧美琴窜访捷克 外交部回应联合利华开始重组专访95后高颜值猪保姆胖东来员工每周单休无小长假男子被流浪猫绊倒 投喂者赔24万小米汽车超级工厂正式揭幕黑马情侣提车了西双版纳热带植物园回应蜉蝣大爆发当地回应沈阳致3死车祸车主疑毒驾恒大被罚41.75亿到底怎么缴妈妈回应孩子在校撞护栏坠楼外国人感慨凌晨的中国很安全杨倩无缘巴黎奥运校方回应护栏损坏小学生课间坠楼房客欠租失踪 房东直发愁专家建议不必谈骨泥色变王树国卸任西安交大校长 师生送别手机成瘾是影响睡眠质量重要因素国产伟哥去年销售近13亿阿根廷将发行1万与2万面值的纸币兔狲“狲大娘”因病死亡遭遇山火的松茸之乡“开封王婆”爆火:促成四五十对奥巴马现身唐宁街 黑色着装引猜测考生莫言也上北大硕士复试名单了德国打算提及普京时仅用姓名天水麻辣烫把捣辣椒大爷累坏了